Fiber Alignment | Ribbon |
Fiber Type | SM (G.652); MM (G.651); DS (G.653); NZDS (G.655) |
Fiber Dimensions | Single: Cladding diameter: 125㎛; Coating diameter 250: 900㎛ Ribbon: Cladding diameter: 125㎛; Ribbon fiber thickness 0.25 to 0.40mm |
Fiber Setting & Cleaved Length | 10mm |
Splicing Modes | Splice mode: 300, Heat mode: 100; Strip mode: 50 |
Typical Splice Loss | SM: 0.05dB, MM: 0.02dB, DS: 0.08dB, NZDS: 0.08dB |
Return Loss (dB) Min | > 60dB |
Splicing Time | Typical 20 sec. with standard SM (ITU-T G.652) |
Sleeve Heating Time | 1~2 core 20 sec.; 4-12 core 50 sec. |
Applicable Protection Sleeves | 40mm, 60mm (fiber) |
Storage of Splice Result | The last 10,000 results to be stored in the internal memory |
Tension Test | 2N/4.4N |
Storage Conditions | Temperature: 40°F~176°F, Humidity: 0~95% |
Dimensions | 215mm x 136mm x 132mm (excluding bumper) |
Number of Splice Cycles with Battery | Typically 236 Cycles |
Electrode Life | 1,500 Splices |
Blade Life | 3,650 Cleaves |
Weight | 2.3kg (including battery) |
Power Supply | 100~240V AC |
Field of View | 20X |
Magnification | 60X |